Service and Maintenance for Cylindrical Locks
5–8 W Series Service Manual
Reinstalling
components for
IDH Max cylindrical
locks
Task A. To pull the field wire harness through the door:
1. Feed the field wire harness (connected to the inside escutcheon)
into the field harness & RH/RHRB reader wire hole and down into
the hole drilled through the door to the hinge mortise.
2. From the latch edge of the door, fish the field wire harness through
the door to the hinge mortise.
3. Make sure there are 3 to 4 of slack in the field wire harness to
allow access to the control electronics circuit board in the inside
escutcheon.
Note: You can let the inside escutcheon dangle from the field wire
harness while completing Task B through Task E.
4. Trim the four leads of the field wire harness. Leave sufficient length
to connect to the wire transfer hinge.
5. Splice the power and communication field wiring to the four pairs
of leads on the frame side of the hinge, following the hinge
manufacturer’s instructions.
Figure 5.9 Pulling the field wire harness through the door
Hinge mortise
Field wire
harness
Inside escutcheon
Field harness &
RH/RHRB reader
wire hole