Service and Maintenance for Cylindrical Locks
5–26 W Series Service Manual
REPLACING COMPONENTS FOR CYLINDRICAL LOCKS
Removing and
reinstalling the
solenoid
Because of the complex nature of this procedure, BEST recommends
that you order a new cylindrical chassis. Contact your BEST
representative.
Use the part numbers listed in Reversing the solenoid when changing
the function when ordering a new cylindrical chassis.
Removing and
reinstalling the
RQE rose liner for
cylindrical locks
Removing the RQE rose liner
1. For IDH Max Locks
Remove the access door. See Task C. To remove the access door:
on page 5–4.
Remove the inside lever/knob. See Task B1. To remove the keyed
lever/knob: on page 5–3.
Remove the upper and lower escutcheon screws from the inside
escutcheon.
Remove the inside hub washers.
Note: You can let the inside escutcheon dangle from the field wire
harness while completing this task.
For electrified locks
Remove the inside lever/knob. See Task B2. To remove the plain
lever/knob: on page 5–4.
Insert the solid, curved end of the spanner wrench in between
the inside rose and the sleeve, as shown in Figure 5.25. Pry the
rose until it pops off the liner.
2. Disconnect the RQE connector.