Installation Instructions for 83KW/93KW–85KW/95KW IDH Max Cylindrical Locks
BEST ACCESS SYSTEMS
Indianapolis, Indiana
19
Installation Instructions for 83KW/93KW–85KW/95KW IDH Max Cylindrical Locks
Installing the panel interface module
23 Connect field wiring from wire transfer
hinge to panel interface module
1 Connect the two communication field wires (run from
the wire transfer hinge) to the COM+ and COM–
terminals on the panel interface circuit board.
Note: The field wire harness leads, connected to the door
side of the wire transfer hinge, are described in the table
below.
2 If you are providing power to the lock through the
panel interface module, connect the two power field
wires (run from the wire transfer hinge) to the 12V and
GND terminals on the panel interface circuit board.
Note: JP2 and JP3, shown in Figure 22a, are used for
manufacturing purposes only.
3 Connect the RS-485 shield wire to one of the GND
terminals on J1.
Wire Color
Ground Black
12 VDC Red
Com+ Orange
Com– Green
IDH Panel Interface
Figure 22a Panel interface circuit board
Figure 22b Connecting field wiring from the wire transfer
hinge
Connect to wire
transfer hinge.