
Service and Maintenance for Mortise Locks
W Series Service Manual 4–13
Reinstalling
components for
IDH Max Mortise
Locks
Task A. To pull the field wire harness through the door:
1. Feed the field wire harness (connected to the inside escutcheon)
into the field harness & reader wire hole and down into the mortise
cavity.
2. From the hinge edge of the door, fish the field wire harness through
the door to the hinge mortise.
Note: You can let the inside escutcheon dangle from the field wire
harness while completing Task A through Task F.
3. Trim the four leads of the field wire harness. Leave sufficient length
to connect to the wire transfer hinge.
4. Splice the power and communication field wiring to the four pairs
of leads on the frame side of the hinge, following the hinge
manufacturer’s instructions.
Figure 4.13 Pulling the field wire harness through the door
Hinge mortise
Field wire
harness
Inside escutcheon
Field harness &
reader wire
hole
Inside of door
Komentarze do niniejszej Instrukcji